1. E-34
The initial value of K calculated by a weight sensor is above and under “±28” as value of HEX.
2. E-35
The value of A is “-” as a weight sensor calculates.
3. E-36
The door opens during sensor cooking.
4. E-41
Gas Sensor Error - Open
5. E-42
Gas Sensor Error - Short
6. E-43
T1 Max Time Error
8. E-45
Cooling Error (3 minutes)
9. E-46
Primary Open Error (3 minutes)
10. E-47
The door opens during cooking
11. E-51
Easy/PH Sensor Error - Open (Sense Failure)
12. E-53
Easy/PH Sensor Error - Read/Write Error
13. E-54
Easy/PH Sensor Error - Zero not to be set
14. E-61
EEPROM Error Case - Open
15. E-62
EEPROM Error Case - Short
16. E-63
EEPROM Error Case - T1 Max Time Error
17. E-01
Door opens when it should not be opened.
18. E-02
Cooking Time Setting Over Error (MWO)
19. E-03
Cooking Time Setting Over Error (Grill)
20. E-04
Cooking Time Setting Over Error (Convection)
21. E-05
Cooking Time Setting Over Error (Combination)
22. E-06
It fails to sense that the swing heater has stopped for 20 seconds during cooking.
23. E-08
Function of MWO starts with spit inserted into cavity inside.
24. E-09
The damper is not set to be positioned for 2 minutes.